SUNOCO PIPELINE L.P.
hazardous_liquid Incident —
Incident Information
| Report Date | — |
| Operator | SUNOCO PIPELINE L.P. |
| Commodity | — |
| Pipeline Type | hazardous_liquid |
Location
| State | |
| Coordinates | 32.06784, -96.47049 |
Cause
| Cause | CORROSION FAILURE |
| Subcause | — |
Casualties
| Fatalities | 0 |
| Injuries | 0 |
Costs
| Property Damage | — |
| Lost Commodity | — |
| Public/Private Damage | — |
| Emergency Response | — |
| Environmental Remediation | — |
| Other Costs | — |
Location Map
Incident Narrative
DURING NORMAL STATION CHECKS ON 10/29/2016 OPERATOR PERSONNEL OBSERVED A CRUDE ODOR INSIDE THE TANK 2603 CONTAINMENT AREA. FURTHER INVESTIGATION REVEALED A SMALL STAINED AREA NEAR THE FILL LINE TO TANK 2603. SUBSEQUENT EXCAVATION REVEALED AN INTERNAL CORROSION PINHOLE IN THE 16"" FILL LINE. THE FILL LINE WAS NOT ACTIVE AT THE TIME OF DISCOVERY AND A SKINNER CLAMP WAS INSTALLED. CONTAMINATED SOIL WAS EXCAVATED FOR ONSITE REMEDIATION. THE AFFECTED PIPING HAS BEEN REMOVED, NEW PIPING INSTALLED AND THE BELOW GRADE PIPING WAS BROUGHT ABOVE GRADE AND THE LINE RETURNED TO SERVICE.