PHILLIPS 66 PIPELINE LLC

hazardous_liquid Incident —

Incident Information

Report Date
OperatorPHILLIPS 66 PIPELINE LLC
Commodity—
Pipeline Typehazardous_liquid

Location

State
Coordinates30.17045, -93.33837

Cause

CauseEQUIPMENT FAILURE
Subcause—

Casualties

Fatalities0
Injuries0

Costs

Property Damage
Lost Commodity
Public/Private Damage
Emergency Response
Environmental Remediation
Other Costs

Location Map

Incident Narrative

AT APPROXIMATELY 16:20 ON 1/23/2017, WHILE MAKING ROUTINE ROUNDS, THE FACILITY OPERATOR SMELLED PRODUCT. UPON INVESTIGATION HE OBSERVED PRODUCT BEING RELEASED FROM THE FLANGE OF A 2"" VALVE THAT WAS ATTACHED TO A 2"" RISER ATTACHED TO THE TRANS-MIX TANK 49 AND 50 COMMON HEADER PIPING. THE OPERATOR MADE NOTIFICATIONS, MOVEMENTS INTO THE FACILITY WERE SHUTDOWN AND ALL SOURCES TO THE SYSTEM WERE ISOLATED. UPDATE 4/03/2017 UPON INVESTIGATION OF GASKET IT SHOWED SIGNS PRIOR DAMAGE AND EMBRITTLEMENT. SIMILAR GASKETS IN THE FACILITY WERE REMOVED AND REPLACED DURING FACILITY DOWNTIME IN MARCH 2017. NO SIMILAR ISSUES WERE FOUND WITH REPLACED GASKETS.