MAGELLAN PIPELINE COMPANY, LP

hazardous_liquid Incident —

Incident Information

Report Date
OperatorMAGELLAN PIPELINE COMPANY, LP
Commodity—
Pipeline Typehazardous_liquid

Location

State
Coordinates34.77809, -92.17880

Cause

CauseINCORRECT OPERATION
Subcause—

Casualties

Fatalities0
Injuries0

Costs

Property Damage
Lost Commodity
Public/Private Damage
Emergency Response
Environmental Remediation
Other Costs

Location Map

Incident Narrative

LOCAL PERSONNEL DETERMINED THE FILTER VESSEL NEEDED TO BE CHECKED. THE SUMP WAS PLACED IN TEST MODE AND A DRAIN VALVE WAS OPENED FROM THE FILTER VESSEL TO THE SUMP TO DRAIN THE FILTER VESSEL. THE FILTER VESSEL WAS PLACED BACK IN SERVICE WITH THE DRAIN VALVE LEFT OPEN AND THE SUMP STILL IN TEST MODE. WHEN MAINLINE PRESSURE WAS INTRODUCED TO THE FILTER VESSEL, PRODUCT FLOWED THROUGH THE OPEN DRAIN VALVE AND IMMEDIATELY BEGAN TO FILL THE SUMP. WITH THE SUMP IN TEST MODE, A HIGH LEVEL ALARM DID NOT COME INTO OPERATIONS CONTROL. THE SWITCH IN THE SUMP TURNED THE PUMP ON BUT THE PUMP WAS UNABLE TO KEEP UP WITH THE PRODUCT INFLOW, RESULTING IN A SUMP OVERFILL. APPROXIMATELY 68 CUBIC YARDS OF SOIL WAS REMEDIATED