STATELINE CRUDE, LLC

hazardous_liquid Incident — — April 11, 2017

Incident Information

Incident DateApril 11, 2017
OperatorSTATELINE CRUDE, LLC
CommodityCRUDE OIL
Pipeline Typehazardous_liquid

Location

State
Coordinates31.97251, -103.75027

Cause

CauseEQUIPMENT FAILURE
SubcausePUMP OR PUMP-RELATED EQUIPMENT

Casualties

Fatalities0
Injuries0

Costs

Property Damage$0
Emergency Response$0
Other Costs$803

Location Map

Incident Narrative

THIS INCIDENT WAS CAUSED BY EQUIPMENT FAILURE. TRANSFER PUMP FAILED DUE TO POWER OUTAGE WHICH RESULTED IN OVERFILLING THE BREAKOUT TANKS. APPROXIMATELY 25 BBLS OF CRUDE WAS SPILLED INSIDE LINED SPCC BERM. THE LINED CONTAINMENT ALLOWED FOR A 100% RECOVERY OF SPILLED FLUIDS. THIS SPILL DID NOT IMPACT THE ENVIRONMENT. CORRECTIVE ACTIONS: 1. LINED CONTAINMENT AND TANKS WERE PRESSURE WASHED; ALL FLUIDS WERE RECOVERED AND DISPOSED 2. TRANSFER PUMP WAS REPAIRED AND ADDITIONAL 40 HORSEPOWER PUMP WAS INSTALLED 3. BACKUP POWER GENERATOR WAS INSTALLED 4. WPX IS PLANNING TO INSTALL FOUR ADDITIONAL 500 BBL TANKS TO INCREASE THE STORAGE VOLUME