NUSTAR LOGISTICS, L.P.

hazardous_liquid Incident — — June 11, 2017

Incident Information

Incident DateJune 11, 2017
OperatorNUSTAR LOGISTICS, L.P.
CommodityCRUDE OIL
Pipeline Typehazardous_liquid

Location

State
Coordinates35.78817, -101.38390

Cause

CauseCORROSION FAILURE
SubcauseINTERNAL CORROSION

Casualties

Fatalities0
Injuries0

Costs

Property Damage$3,670
Emergency Response$1,570
Other Costs$2,200

Location Map

Incident Narrative

NUSTAR'S CONTROL CENTER RECEIVED A NOTIFICATION REGARDING A POSSIBLE LEAK AT NUSTAR'S DIAL PUMP STATION FROM A PASSING MOTORIST. THE PIPELINE WAS SHUT DOWN AND OPERATIONS PERSONNEL WERE DISPATCHED TO THE STATION. THE STATION WAS BLOCKED IN AND REPAIRS MADE. A SECTION OF PIPING AND DISCHARGE FLANGE CONTAINING A PINHOLE WAS REMOVED AND ANALYZED. UPDATE: THE FAILURE OCCURRED DUE TO MICROBIOLOGICALLY INDUCED CORROSION OF THE INTERNAL SURFACE OF THE FLANGE SIDE OF THE PIPE TO FLANGE WELD ON THE DISCHARGE ARM OF THE PUMP STATION.

About This Pipeline Incident

Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.

Back to All Incidents More Incidents in