NUSTAR PERMIAN TRANSPORTATION AND STORAGE, LLC

hazardous_liquid Incident — — August 23, 2017

Incident Information

Incident DateAugust 23, 2017
OperatorNUSTAR PERMIAN TRANSPORTATION AND STORAGE, LLC
CommodityCRUDE OIL
Pipeline Typehazardous_liquid

Location

State
Coordinates32.52911, -100.85469

Cause

CauseEQUIPMENT FAILURE
SubcauseOTHER EQUIPMENT FAILURE

Casualties

Fatalities0
Injuries0

Costs

Property Damage$54
Emergency Response$10,833
Other Costs$0

Location Map

Incident Narrative

A MOTOR OPERATED VALVE WENT CLOSED (UN-COMMANDED) WHILE MAKING A DELIVERY TO A THIRD PARTY TERMINAL. THE SUBSEQUENT PRESSURE INCREASE CAUSED TWO O-RINGS TO FAIL ON STRAINER BASKETS INSIDE NUSTAR'S COLORADO CITY TERMINAL. THE FAILED O-RINGS WERE REPLACED. UPDATE - THE CAUSE OF THE ACCIDENT WAS THE OVER-PRESSURIZATION OF THE ANSI 150 COMPONENTS INSIDE NUSTAR'S COLORADO CITY TERMINAL DUE TO AN UN-COMMANDED VALVE CLOSURE FROM A DEFECTIVE FLOW SWITCH. A CONTRIBUTING CAUSE WAS THE FAILURE OF THE TERMINAL'S OVER-PRESSURE PROTECTION SYSTEM.

About This Pipeline Incident

Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.

Back to All Incidents More Incidents in