NUSTAR LOGISTICS, L.P.

hazardous_liquid Incident — — August 23, 2017

Incident Information

Incident DateAugust 23, 2017
OperatorNUSTAR LOGISTICS, L.P.
CommodityREFINED AND/OR PETROLEUM PRODUCT (NON-HVL) WHICH IS A LIQUID
Pipeline Typehazardous_liquid

Location

State
Coordinates34.88694, -106.22806

Cause

CauseCORROSION FAILURE
SubcauseINTERNAL CORROSION

Casualties

Fatalities0
Injuries0

Costs

Property Damage$19,102
Emergency Response$4,485
Other Costs$2,408

Location Map

Incident Narrative

DURING A ROUTINE SURVEY, NUSTAR OPERATING PERSONNEL DISCOVERED A LEAK ON A 6-INCH AUXILIARY VALVE AT MAINLINE VALVE MBV240. THE PIPELINE SYSTEM WAS SHUTDOWN. THE FLANGED VALVE WAS REMOVED, AND PERMANENT REPAIRS WERE MADE BY BLINDING THE FLANGE. UPDATE - THE FAILURE WAS DUE TO INTERNAL CORROSION OF THE VALVE'S SOFT IRON BONNET GASKET, AND, TO A LESSER EXTENT, CORROSION OF THE VALVE BODY GASKET SEAT.

About This Pipeline Incident

Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.

Back to All Incidents More Incidents in