DCP MIDSTREAM

hazardous_liquid Incident — — January 5, 2019

Incident Information

Incident DateJanuary 5, 2019
OperatorDCP MIDSTREAM
CommodityHVL OR OTHER FLAMMABLE OR TOXIC FLUID WHICH IS A GAS AT AMBI
Pipeline Typehazardous_liquid

Location

State
Coordinates29.10321, -95.86846

Cause

CauseEQUIPMENT FAILURE
SubcauseTHREADED CONNECTION/COUPLING FAILURE

Casualties

Fatalities0
Injuries0

Costs

Property Damage$46,015
Emergency Response$0
Other Costs$0

Location Map

Incident Narrative

"AT APPROXIMATELY 2:30 PM ON 1/5/2019, A DCP TECHNICIAN WAS NOTIFIED BY DCP'S HOUSTON CONTROL CENTER (HCC) OF A GAS DETECTOR ALARM ORIGINATING FROM THE ASHWOOD PUMP STATION LOCATED IN ASHWOOD, TX. UPON ARRIVING ONSITE AT 3:15PM, THE FIELD TECHNICIAN FOUND A SMALL LEAK ARISING FROM A NIPPLE ON THE LOW POINT DRAIN OF THE DISCHARGE SIDE OF PUMP #2. THE LEAKING COMPONENT WAS THEN ISOLATED AND THE RESIDUAL NGL IN THE ENSUING PIPELINE WAS FLARED. THE LEAK WAS REPAIRED BY REMOVING THE NIPPLE AND PLUGGING THE ORIFICE. CORRECTIVE ACTION: THE FAILED COMPONENT WAS SENT TO STRESS ENGINEERING FOR EXAMINATION. THE ANALYSIS DETERMINED THAT THE FRACTURE WHICH DEVELOPED IN THE NIPPLE WAS AS A RESULT OF REVERSE BENDING FATIGUE WHICH IS TYPICALLY ASSOCIATED WITH VIBRATION."