HARVEST MIDSTREAM COMPANY

hazardous_liquid Incident — — May 1, 2019

Incident Information

Incident DateMay 1, 2019
OperatorHARVEST MIDSTREAM COMPANY
CommodityCRUDE OIL
Pipeline Typehazardous_liquid

Location

State
Coordinates28.40872, -98.21365

Cause

CauseINCORRECT OPERATION
SubcauseWRONG EQUIPMENT SPECIFIED OR INSTALLED

Casualties

Fatalities0
Injuries0

Costs

Property Damage$800
Emergency Response$0
Other Costs$0

Location Map

Incident Narrative

A HARVEST OPERATOR ARRIVED AT THE THREE RIVERS STATION AND FOUND A NEEDLE VALVE ASSOCIATED WITH THE CHEMICAL INJECTION QUILL ASSEMBLY LEAKING. THE OPERATOR IMMEDIATELY NOTIFIED THE CONTROL CENTER AND THE PUMPS AT THE STATION WERE SHUT-IN UNTIL THE LEAK COULD BE STOPPED. ALL OTHER APPROPRIATE NOTIFICATIONS WERE MADE. THE CHEMICAL INJECTOR ASSEMBLY WAS REMOVED AND THE VALVE WAS CLOSED AND PLUGGED. THE OPERATOR NOTIFIED THE CONTROL ROOM AND THE LINE WAS PUT BACK INTO SERVICE. TYPE OF EVENT: EQUIPMENT FAILURE VALVE FAILED DUE TO INTERNAL CORROSION. DIRECT CAUSE: DEFECTIVE EQUIPMENT VALVE MATERIAL OF CONSTRUCTION NOT SUITABLE FOR INTENDED SERVICE. THE FAILED VALVE WAS CONSTRUCTED OF CARBON STEEL AND THE RECOMMENDED MATERIAL FOR THE INJECTION VALVE IS STAINLESS STEEL. ROOT CAUSE: INADEQUATE MONITORING OF INSTALLATION VISUALLY THE VALVES APPEARS SIMILAR TO A STAINLESS STEEL WITH AN IDENTIFIER STENCILED INTO THE BODY OF THE VALVE INDICATING CARBON STEEL. CORRECTIVE ACTIONS IT WAS VERIFIRED THAT ALL OTHER CHEMICAL INJECTIONS VALVES ON THE PEARSALL PIPELINE SYSTEM WERE CONSTRUCTED OF THE PROPER MATERIAL.

About This Pipeline Incident

Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.

Back to All Incidents More Incidents in