MARATHON PIPE LINE LLC

hazardous_liquid Incident —

Incident Information

Report Date
OperatorMARATHON PIPE LINE LLC
Commodity—
Pipeline Typehazardous_liquid

Location

State
Coordinates36.97082, -94.31477

Cause

CauseINCORRECT OPERATION
Subcause—

Casualties

Fatalities0
Injuries0

Costs

Property Damage
Lost Commodity
Public/Private Damage
Emergency Response
Environmental Remediation
Other Costs

Location Map

Incident Narrative

ON DECEMBER 12, 2017, PERSONNEL WERE ON-SITE, COMPLETING PROJECT WORK TO DRAIN DOWN AN OUT-OF-SERVICE PUMP WHEN THE RELEASE OCCURRED. THE VENT VALVE ON TOP OF THE PUMP WAS CONNECTED VIA TUBING TO THE PUMP SEAL CAVITY, AS A MEANS OF PROVIDING THERMAL PROTECTION FOR UNIT 4 WHICH WAS OUT-OF-SERVICE AT THE TIME. WHEN THE UNIT SUCTION AND DISCHARGE VALVES WERE OPENED, PRODUCT FILLED THE UNIT AND FLOWED THROUGH THE VENT VALVE, OVERWHELMING THE PUMP SEAL CAVITY DRAIN. INVESTIGATION FINDINGS INDICATE THE CAUSE WAS DUE TO A PROJECT-SPECIFIC PROCEDURE THAT WAS INADEQUATE. PROCEDURE IMPROVEMENTS ARE BEING CONSIDERED FOR FUTURE PROJECT WORK. 2/27/18: PART C, QUESTION 3 - UPDATED ITEM INVOLVED TO ""OTHER - OVERFLOWED PUMP SEAL CAVITY"". PART C, QUESTION 4 - UPDATED THE YEAR INSTALLED TO 1949. PART D, QUESTION 7 - CORRECTED OUR RESPONSE TO ""NO"". PART H - UPDATED THE NARRATIVE WITH INVESTIGATION RESULTS.