MAGELLAN PIPELINE COMPANY, LP
hazardous_liquid Incident —
Incident Information
| Report Date | — |
| Operator | MAGELLAN PIPELINE COMPANY, LP |
| Commodity | — |
| Pipeline Type | hazardous_liquid |
Location
| State | |
| Coordinates | 46.87957, -96.87974 |
Cause
| Cause | NATURAL FORCE DAMAGE |
| Subcause | — |
Casualties
| Fatalities | 0 |
| Injuries | 0 |
Costs
| Property Damage | — |
| Lost Commodity | — |
| Public/Private Damage | — |
| Emergency Response | — |
| Environmental Remediation | — |
| Other Costs | — |
Location Map
Incident Narrative
AN OPERATOR WAS PERFORMING A TANK FARM INSPECTION AND NOTICED PRODUCT STAINED SNOW NEXT TO TANK 677. UPON INVESTIGATION, THE OPERATOR NOTICED A MIST OF PRODUCT COMING FROM THE1/4"" QUICK CONNECT TEST PORT FITTING ON THE THERMAL RELIEF SYSTEM AROUND THE TANK RECEIVE VALVE. THE APPARENT CAUSE OF THE RELEASE WAS ICE ACCUMULATION IN THE QUICK CONNECT FITTING. THE RELEASE WAS ISOLATED BY CLOSING THE VALVE ON THE RELIEF SYSTEM LEADING TO THE QUICK CONNECT FITTING. THE VALVE AND THE QUICK CONNECT FITTING WERE REPLACED. FOLLOWING THE RELEASE, THE REMAINING QUICK CONNECT FITTINGS ON OTHER THERMAL RELIEF SYSTEMS WERE CHECKED AND TEST PORT VALVES WERE CONFIRMED CLOSED. NO EVIDENCE OF A DAMAGE WAS DISCOVERED ON THE OTHER THERMAL RELIEF SYSTEMS. MAGELLAN WAS UNABLE TO UPLOAD THE 7000-1 ACCIDENT REPORT FOR THE RELEASE DUE TO THE PHMSA PORTAL BEING DOWN. TO COMPLY WITH THE 30 DAY SUBMITTAL DEADLINE, MAGELLAN PROVIDED EMAIL COPIES TO THE INDIVIDUALS LISTED BELOW. INDIVIDUALS EMAILED A COPY OF THE 7000-1 REPORT ON 02/07/2018: [email protected]; [email protected]; [email protected]
About This Pipeline Incident
Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.