KINDER MORGAN LIQUID TERMINALS, LLC

hazardous_liquid Incident —

Incident Information

Report Date
OperatorKINDER MORGAN LIQUID TERMINALS, LLC
Commodity—
Pipeline Typehazardous_liquid

Location

State
Coordinates29.73320, -95.20490

Cause

CauseNATURAL FORCE DAMAGE
Subcause—

Casualties

Fatalities0
Injuries0

Costs

Property Damage
Lost Commodity
Public/Private Damage
Emergency Response
Environmental Remediation
Other Costs

Location Map

Incident Narrative

AT 11:50 ON 1-18-18 A LEAK WAS IDENTIFIED AT THE PASADENA GP MANIFOLD ON THE 20"" CROSS CHANNEL LINE. THE 4"" DRAIN VALVE HAD RUPTURED DUE TO RESIDUAL WATER FREEZING DURING AN UNNATURAL FREEZING TEMPERATURE EVENT. REPLACEMENT VALVE WAS INSTALLED. CORRECTIVE ACTION: ALL LOW POINT DRAIN VALVES IN THE FACILITY WERE CHECK TO MAKE SURE FREEZING TEMPERATURES DID NOT DAMAGE THE VALVES. PLAN TO PREVENT REOCCURRENCE: A PREVENTATIVE MAINTENANCE TASK HAS BEEN IMPLEMENTED TO INSPECT ALL LOW POINT DRAIN VALVES ON AN ANNUAL BASIS AND PRIOR TO ANY WEATHER EVENT THAT INDICATES FREEZING TEMPERATURES.