ENTERPRISE CRUDE PIPELINE LLC
hazardous_liquid Incident —
Incident Information
| Report Date | — |
| Operator | ENTERPRISE CRUDE PIPELINE LLC |
| Commodity | — |
| Pipeline Type | hazardous_liquid |
Location
| State | |
| Coordinates | 35.94020, -96.74310 |
Cause
| Cause | EQUIPMENT FAILURE |
| Subcause | — |
Casualties
| Fatalities | 0 |
| Injuries | 0 |
Costs
| Property Damage | — |
| Lost Commodity | — |
| Public/Private Damage | — |
| Emergency Response | — |
| Environmental Remediation | — |
| Other Costs | — |
Location Map
Incident Narrative
ON 02-05-2018 AT APPROXIMATELY 20:15 HOURS, LOCAL OPERATING PERSONNEL DISCOVERED 2 BARREL OF CRUDE OIL UNDERNEATH THE TANK 1010 INLET FLANGE. DURING THE INVESTIGATION IT WAS DETERMINED THAT THE INLET PIPING HAD EXCEED MOP DUE TO THERMAL EXPANSION. A TRV WAS INSTALLED TO PREVENT RE-OCCURRENCE. ALL CRUDE WAS CLEANED UP AND THE PIPING RETURNED TO SERVICE.