MID-CONTINENT FRACTIONATION AND STORAGE, L.L.C.
hazardous_liquid Incident — — March 1, 2018
Incident Information
| Incident Date | March 1, 2018 |
| Operator | MID-CONTINENT FRACTIONATION AND STORAGE, L.L.C. |
| Commodity | HVL OR OTHER FLAMMABLE OR TOXIC FLUID WHICH IS A GAS AT AMBI |
| Pipeline Type | hazardous_liquid |
Location
| State | |
| Coordinates | 38.37220, -98.07262 |
Cause
| Cause | EQUIPMENT FAILURE |
| Subcause | NON-THREADED CONNECTION FAILURE |
Casualties
| Fatalities | 0 |
| Injuries | 0 |
Costs
| Property Damage | $1 |
| Emergency Response | $560 |
| Other Costs | $0 |
Location Map
Incident Narrative
AT 7:35 PM ON 3/1/2018 THE PIPELINE CONTROLLER RECEIVED A SHUTDOWN ALARM FOR THE MITCHELL STATION NEAR THE METER RUNS. THE SHUTDOWN OCCURRED DUE TO HIGH HAZARDOUS GAS LEVELS. THE CONTROLLER SENT A TECHNICIAN TO THE MITCHELL FACILITY TO INVESTIGATE. THE CONTROLLER IMMEDIATELY BEGAN TO PAN A SECURITY CAMERA TO THE AREA TO SEARCH FOR THE HAZARDOUS GAS SOURCE. DUE TO THE CHARACTERISTICS OF THE ETHANE/PROPANE MIX AND WEATHER CONDITIONS, IT WAS DIFFICULT TO DETERMINE THE SOURCE OF THE LEAK. THE TECHNICIAN ARRIVED ON SCENE AND EVALUATED THE SITUATION AND NOTIFIED THE CONTROLLER THAT THE LEAK WAS LOCATED NEAR THE ENCLOSURE OF VF-11101 (COALESCING FILTER). BASED ON THE LEAK LOCATION INFORMATION, THE CONTROLLER FURTHER ISOLATED THE LEAK BY REMOTELY CLOSING ADJACENT VALVES. THE LEAK WAS FULLY STOPPED BY 10:30 PM AND THE SITE WAS RENDERED SAFE. A SECONDARY FILTER WAS USED TO PLACE THE FACILITY BACK IN SERVICE AT 11:30 PM. THE FILTER WAS BLOWN DOWN AND PURGED WITH NITROGEN. THE SOURCE OF THE LEAK WAS IDENTIFIED AS THE PRESSURE WARNING DEVICE O-RING. THE PRESSURE WARNING DEVICE WAS REMOVED AND THE DEFECTIVE O-RING WAS REPLACED. THE PRESSURE WARNING DEVICE WAS REINSTALLED BUT THE FILTER WAS LEFT OUT OF SERVICE UNTIL THE ROOT CAUSE ANALYSIS WAS PERFORMED. THE RCA CONFIRMED THAT THE O-RING WAS THE ONLY FAILED COMPONENT AND THAT NO OTHER HAZARDS EXISTED; AS A RESULT, THE FILTER WAS PLACED BACK IN SERVICE ON MONDAY (3/5/2018) AT 2:00 PM.
About This Pipeline Incident
Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.