KINDER MORGAN LIQUID TERMINALS, LLC

hazardous_liquid Incident —

Incident Information

Report Date
OperatorKINDER MORGAN LIQUID TERMINALS, LLC
Commodity—
Pipeline Typehazardous_liquid

Location

State
Coordinates29.72536, -95.20334

Cause

CauseEQUIPMENT FAILURE
Subcause—

Casualties

Fatalities0
Injuries0

Costs

Property Damage
Lost Commodity
Public/Private Damage
Emergency Response
Environmental Remediation
Other Costs

Location Map

Incident Narrative

ON 6/1/2018, USLD WAS OBSERVED IN CONTAINMENT AT PASADENA TERMINAL'S GP MANIFOLD. UPON INVESTIGATION, IT WAS DISCOVERED THAT THE THERMAL PRESSURE RELIEF VALVE WAS POPPING OFF TO RELIEF THERMAL PRESSURE BUT FAILED TO SEAT PROPERLY. AS THE PRODUCT FILLED THE SUMP, THE PUMP TO REMOVE PRODUCT FAILED TO ENGAGE WHICH CAUSED PRODUCT TO OVERFLOW UNTO CONTAINMENT. PRODUCT WAS REMOVED VIA VACUUM TRUCK AND THE THERMAL RELIEF VALVE REPLACED. CORRECTIVE ACTIONS: ALL DISCHARGE FROM RELIEF VALVES ARE BEING PIPED DIRECTLY INTO A TRANSMIX TANK TO PREVENT THIS FROM REOCCURRING.

About This Pipeline Incident

Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.

Back to All Incidents More Incidents in