ONEOK NGL PIPELINE, LLC
hazardous_liquid Incident —
Incident Information
| Report Date | — |
| Operator | ONEOK NGL PIPELINE, LLC |
| Commodity | — |
| Pipeline Type | hazardous_liquid |
Location
| State | |
| Coordinates | 35.54874, -99.29455 |
Cause
| Cause | EQUIPMENT FAILURE |
| Subcause | — |
Casualties
| Fatalities | 0 |
| Injuries | 0 |
Costs
| Property Damage | — |
| Lost Commodity | — |
| Public/Private Damage | — |
| Emergency Response | — |
| Environmental Remediation | — |
| Other Costs | — |
Location Map
Incident Narrative
PANTHER CREEK PLANT OPERATOR NOTIFIED THE LOCAL PIPELINE OPERATOR OF A LEAK ON THE PIPELINE METER SKID. UPON ARRIVAL, THE PIPELINE OPERATOR IDENTIFIED THE LEAK TO BE A PIPE NIPPLE ON THE METER SKID. THE SECTION OF PIPE WITH THE LEAKING PIPE NIPPLE WAS ISOLATED, THE NIPPLE WAS REPLACED, AND THE METER SKID WAS RETURNED TO SERVICE. UPON INVESTIGATION, IT WAS DETERMINED THAT A POSSIBLE CAUSE WAS VIBRATION FROM PLANT PUMPS. THE PLANT EVALUATED THE PULSATION DAMPENERS AND ADDED NITROGEN TO CORRECT THE ISSUE. 18/08/08 - UPDATED NARRATIVE AND TIME AND DATE OF ACCIDENT. NJONES
About This Pipeline Incident
Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.