ENTERPRISE PRODUCTS OPERATING LLC

hazardous_liquid Incident —

Incident Information

Report Date
OperatorENTERPRISE PRODUCTS OPERATING LLC
Commodity—
Pipeline Typehazardous_liquid

Location

State
Coordinates29.68172, -95.01481

Cause

CauseEQUIPMENT FAILURE
Subcause—

Casualties

Fatalities0
Injuries0

Costs

Property Damage
Lost Commodity
Public/Private Damage
Emergency Response
Environmental Remediation
Other Costs

Location Map

Incident Narrative

ON 10/7/2018 AT 7:50 AM LID 914F-100 (LINE 9) WAS LINED UP TO DELIVER INTO TANK 162. SHORTLY AFTER START UP, OPERATOR NOTICED PRODUCT LEAKING ON A 10"" BLIND FLANGE ON TANK 162. THE MOVEMENT WAS SHUT DOWN IMMEDIATELY. IT WAS DISCOVER THAT A 10"" VALVE HAD A BROKEN PIN THAT CONNECTED THE VALVE STEM TO THE SEALING MECHANISM INSIDE THE VALVE BODY. AS A RESULT, THE VALVE INDICATOR SHOWED TO BE OPEN BUT IT REMAINED 100% CLOSED. ADDITIONALLY, THE PRESSURE TRANSMITTER THAT MONITORED THE LINE PRESSURE HAD BLOCKAGE IN THE PORT SO IT DID NOT TRIGGER THE SDV TO CLOSE, RESULTING IN AN OVERPRESSURE. THE OVERPRESSURE CAUSED A LEAK AT THE BLIND FLANGE. NO PRODUCT WAS RECOVERED. THE 10"" VALVE WAS REPLACED AND THE PRESSURE TRANSMITTER PORTS WERE CLEARED OF DEBRIS. TRRC WAS NOTIFIED OF THE ACCIDENT IMMEDIATELY FOLLOWING CONFIRMATION OF VOLUME LOSS EXCEEDING THE 5 GALLON THRESHOLD ON 10/8/2018 AT 17:26HRS; TRRC INCIDENT #1857