SFPP, LP
hazardous_liquid Incident —
Incident Information
| Report Date | — |
| Operator | SFPP, LP |
| Commodity | — |
| Pipeline Type | hazardous_liquid |
Location
| State | |
| Coordinates | 37.99530, -121.76954 |
Cause
| Cause | EQUIPMENT FAILURE |
| Subcause | — |
Casualties
| Fatalities | 0 |
| Injuries | 0 |
Costs
| Property Damage | — |
| Lost Commodity | — |
| Public/Private Damage | — |
| Emergency Response | — |
| Environmental Remediation | — |
| Other Costs | — |
Location Map
Incident Narrative
WHILE CONDUCTING SCHEDULED BLOCK VALVE EXERCISES ON LS-90/50/60 (CONCORD TO FRESNO), THE MAINTENANCE CREW DISCOVERED A STAIN AROUND THE WILLOW PASS BLOCK VALVE IN THE CITY OF ANTIOCH, CA., MEASURING APPROXIMATELY 4.5' IN DIAMETER. THE BURIED PORTION OF THE VALVE WAS EXCAVATED AND IT WAS DETERMINED THAT THE LEAK WAS COMING FROM A THREADED PLUG IN THE BONNET OF THE VALVE. THIS PORTION OF THE LINE WAS ISOLATED AND THE PLUG WAS REMOVED AND REPLACED. THE PLUG WAS FOUND TO HAVE LITTLE TO NO TEFLON TAPE LEFT ON THE THREADS. A NEW PLUG WAS INSTALLED AND SUCCESSFULLY HELD TEST PRESSURE DURING BOTH AN HOUR LONG STATIC TEST AND HOUR LONG RUNNING TEST.
About This Pipeline Incident
Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.