ENTERPRISE PRODUCTS OPERATING LLC

hazardous_liquid Incident —

Incident Information

Report Date
OperatorENTERPRISE PRODUCTS OPERATING LLC
Commodity—
Pipeline Typehazardous_liquid

Location

State
Coordinates29.72070, -95.15869

Cause

CauseEQUIPMENT FAILURE
Subcause—

Casualties

Fatalities0
Injuries0

Costs

Property Damage
Lost Commodity
Public/Private Damage
Emergency Response
Environmental Remediation
Other Costs

Location Map

Incident Narrative

ON 10/26/2018 AT 14:43, PIPELINE CONTROL RECEIVED A GAS DETECTION ALARM ON PUMP 602 AT INTERMEDIATE PUMP STATION (IPS). PERSONNEL ARRIVED AT THE IPS STATION AT 14:48 AND DISCOVERED VAPORS LEAKING FROM THE VALVE STEM PACKING TATTLETALE. FLOW WAS ROUTED, VALVE BLOCKED IN, AND DE-PRESSURED TO PORTABLE FLARE. THE VALVE WAS REMOVED AND REPLACED WITH A NEW VALVE. THE VALVE WAS INSPECTED BY A 3RD PARTY AND IDENTIFIED THE O-RING FAILED DUE TO BALL VALVE BEARING BEING LOOSE AS WELL AS A BUILD UP OF SOLIDS IN VALVE BODY.

About This Pipeline Incident

Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.

Back to All Incidents More Incidents in