MAGELLAN PIPELINE COMPANY, LP
hazardous_liquid Incident —
Incident Information
| Report Date | — |
| Operator | MAGELLAN PIPELINE COMPANY, LP |
| Commodity | — |
| Pipeline Type | hazardous_liquid |
Location
| State | |
| Coordinates | 37.79278, -96.04936 |
Cause
| Cause | EQUIPMENT FAILURE |
| Subcause | — |
Casualties
| Fatalities | 0 |
| Injuries | 0 |
Costs
| Property Damage | — |
| Lost Commodity | — |
| Public/Private Damage | — |
| Emergency Response | — |
| Environmental Remediation | — |
| Other Costs | — |
Location Map
Incident Narrative
OPERATIONS CONTROL RECEIVED A SEAL FAIL ALARM FOR THE PUMP AT EUREKA STATION WHICH PROMPTED IMPLEMENTATION OF PIPELINE SHUTDOWN PROCEDURES. THE STATION WAS ISOLATED AND LOCAL PERSONNEL WERE CONTACTED TO INVESTIGATE. FIELD PERSONNEL CONFIRMED PROPANE WAS BEING RELEASED FROM THE PUMP SEALS. THE RELEASE WAS CAUSED BY POSSIBLE DEBRIS IN THE SEAL FACE. THE PUMP WAS EVACUATED OF PROPANE. THE PUMP WAS FLUSHED AND REFILLED WITH GASOLINE AND RESTARTED. NO INDICATION OF A SEAL LEAK WAS OBSERVED WHILE THE PUMP SAT IDLE IN GASOLINE OR DURING PUMP OPERATION IN GASOLINE. THE PUMP SEALS WERE MONITORED DURING THE NEXT PROPANE BATCH WITH NO SIGNS OF A SEAL LEAK. FUTURE PREVENTATIVE ACTIONS INCLUDE INSPECTING THE PUMP PER THE WEEKLY ENGINE PUMPING UNIT INSPECTION AND ANNUAL PUMPING UNIT SEAL FAILURE SYSTEM INSPECTION PROCEDURES.