ENTERPRISE PRODUCTS OPERATING LLC

hazardous_liquid Incident —

Incident Information

Report Date
OperatorENTERPRISE PRODUCTS OPERATING LLC
Commodity—
Pipeline Typehazardous_liquid

Location

State
Coordinates30.22178, -91.03143

Cause

CauseINCORRECT OPERATION
Subcause—

Casualties

Fatalities0
Injuries0

Costs

Property Damage
Lost Commodity
Public/Private Damage
Emergency Response
Environmental Remediation
Other Costs

Location Map

Incident Narrative

ON 1/5/2019 AT 20:29, DURING ROUTINE PIGGING OPERATIONS AT THE GEISMAR PUMP STATION, A STUCK PIG WAS DISLODGED AND CAUSED THE PIG TRAP DOOR TO BREAK AWAY FROM THE ENCLOSURE. THE PIGS WERE EJECTED AND PRODUCT RELEASED TO THE ATMOSPHERE. HOUSTON CONTROL CENTER AND LOCAL OPERATIONS CLOSED AUTOMATIC AND MANUAL VALVES NEAR THE GEISMAR STATION. THE PIPELINE WAS DEPRESSURIZED AND THE PIG TRAP AREA WAS ISOLATED. THE PIG TRAP DOOR WAS REPLACED AND TESTING WAS PERFORMED TO ENSURE THE INTEGRITY OF THE ENCLOSURE PRIOR TO THE PIG TRAP BEING RETURNED TO SERVICE. INCIDENT INVESTIGATION IDENTIFIED THAT THE PIGGING PROCEDURE DID NOT CONTAIN GUIDANCE ON HOW TO DISLODGE STUCK PIGS. PART A QUESTION 14A - SHUTDOWN TIME HAS BEEN REVISED TO REFLECT COMPLETE AUTOMATIC VALVE CLOSURE. THE NRC 48-HOUR SUPPLEMENTAL CALL WAS PLACED ON JANUARY 7, 2019; NRC #1234759.