ENTERPRISE CRUDE PIPELINE LLC
hazardous_liquid Incident —
Incident Information
| Report Date | — |
| Operator | ENTERPRISE CRUDE PIPELINE LLC |
| Commodity | — |
| Pipeline Type | hazardous_liquid |
Location
| State | |
| Coordinates | 31.48393, -99.69122 |
Cause
| Cause | EQUIPMENT FAILURE |
| Subcause | — |
Casualties
| Fatalities | 0 |
| Injuries | 0 |
Costs
| Property Damage | — |
| Lost Commodity | — |
| Public/Private Damage | — |
| Emergency Response | — |
| Environmental Remediation | — |
| Other Costs | — |
Location Map
Incident Narrative
ON FEBRUARY 4 AT 17:50 LOCAL TIME, THE LOCAL TECHNICIAN AT IVIE LAKE STATION WAS TROUBLESHOOTING AN ISSUE WITH A PRESSURE TRANSMITTER ON THE RECEIVER TRAP. WHEN HE STARTED TO REMOVE THE TERMINATION COVER ON THE TRANSMITTER, THE 3/8"" TUBING LINE CAME LOOSE FROM THE FITTING. HE IMMEDIATELY CLOSED THE ISOLATION VALVE THAT WAS WITHIN REACH. THE TUBING AND FITTINGS WERE REPLACED. TO PREVENT RECURRENCE, THE TECHNICIAN VERIFIED THAT THE TUBING NUTS WERE CORRECTLY SET ON ALL OF THE STATION INSTRUMENTATION.