ENTERPRISE PRODUCTS OPERATING LLC

hazardous_liquid Incident —

Incident Information

Report Date
OperatorENTERPRISE PRODUCTS OPERATING LLC
Commodity—
Pipeline Typehazardous_liquid

Location

State
Coordinates29.72058, -95.15889

Cause

CauseEQUIPMENT FAILURE
Subcause—

Casualties

Fatalities0
Injuries0

Costs

Property Damage
Lost Commodity
Public/Private Damage
Emergency Response
Environmental Remediation
Other Costs

Location Map

Incident Narrative

ON 2/13/2019 AT 19:25, PIPELINE CONTROL RECEIVED A GAS ALARM ON LID 32400 AT INTERMEDIATE PUMP STATION. THE PIPELINE TECH ARRIVED AND DISCOVERED A LEAK ON A FILTER HOUSING PRESSURE ALERT VALVE. AT 19:53, FLOW WAS RE-ROUTED AND FILTER HOUSING WAS ISOLATED AND LEAK STOPPED. ON 2/13/2019 AT 21:02, THE TRRC WAS NOTIFIED. CASE #1936 LAB EXAMINATION CONCLUDED THE O-RING EXHIBITED WEAR/ABRASION AND MECHANICAL DAMAGE MAKRS. THE MECHANICAL DAMAGE IS LIKELY RELATED TO INITIAL INSTALLATION AND ASSEMBLY OF THE PRESSURE ALERT VALVE. THE ABRASION IS LIKELY RELATED TO SUBSEQUENT INSTALLATION/REMOVAL OF THE PRESSURE ALERT VALVE.