HOLLY ENERGY PARTNERS - OPERATING, L.P.

hazardous_liquid Incident —

Incident Information

Report Date
OperatorHOLLY ENERGY PARTNERS - OPERATING, L.P.
Commodity—
Pipeline Typehazardous_liquid

Location

State
Coordinates32.56315, -99.78809

Cause

CauseEQUIPMENT FAILURE
Subcause—

Casualties

Fatalities0
Injuries0

Costs

Property Damage
Lost Commodity
Public/Private Damage
Emergency Response
Environmental Remediation
Other Costs

Location Map

Incident Narrative

DURING NORMAL OPERATIONS, THE HOLLY ENERGY PARTNERS CONTROL CENTER RECEIVED AN LEL VAPOR MONITOR ALARM AT HAWLEY STATION AT 00:22 MT VIA THE SCADA SYSTEM. THE PIPELINE WAS IMMEDIATELY SHUT DOWN AND BLOCKED IN AT 00:22 MT. A TECHNICIAN WAS DISPATCHED TO THE LOCATION TO INVESTIGATE FURTHER. ONCE HOLLY ENERGY PARTNERS PERSONNEL ARRIVED ON-SITE AT 01:05 MT, THEY WERE ABLE TO CONFIRM THAT A PIECE OF STEEL TUBING HAD FAILED ON HAWLEY STATIONS PUMPING UNIT #2. HOLLY ENERGY PARTNERS PERSONNEL ON LOCATION ALSO REPORTED THAT THERE WAS A RELEASE OF PRODUCT FROM THE FAILED TUBING. DURING A ROOT CAUSE INVESTIGATION, IT WAS DETERMINED THAT THE FAILURE WAS A RESULT OF HIGH-FREQUENCY VIBRATION.

About This Pipeline Incident

Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.

Back to All Incidents More Incidents in