EXXONMOBIL PIPELINE CO

hazardous_liquid Incident —

Incident Information

Report Date
OperatorEXXONMOBIL PIPELINE CO
Commodity—
Pipeline Typehazardous_liquid

Location

State
Coordinates30.01079, -90.86089

Cause

CauseEQUIPMENT FAILURE
Subcause—

Casualties

Fatalities0
Injuries0

Costs

Property Damage
Lost Commodity
Public/Private Damage
Emergency Response
Environmental Remediation
Other Costs

Location Map

Incident Narrative

ON MAY 29, 2019 @ 13:15 CST A CONTRACTOR WORKING FOR EXXONMOBIL PIPELINE COMPANY (EMPCO) DISCOVERED A CRUDE OIL RELEASE FROM THE ST JAMES STATION METER PROVER. THE RELEASE OCCURRED BECAUSE THE LOCKING ARMS ON A DC CAMLOCK FITTING ASSOCIATED WITH THE 2"" PROVER DRAIN VALVE WERE FOUND NOT FULLY CLOSED OR PINNED, WHICH ULTIMATELY ALLOWED THE VALVE TO BECOME PARTIALLY OPEN TO THE ENVIRONMENT. THE CAMLOCK FITTING WAS REPLACED WITH A THREADED BULL-PLUG.

About This Pipeline Incident

Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.

Back to All Incidents More Incidents in