DCP MIDSTREAM

hazardous_liquid Incident —

Incident Information

Report Date
OperatorDCP MIDSTREAM
Commodity—
Pipeline Typehazardous_liquid

Location

State
Coordinates28.55865, -98.16367

Cause

CauseEQUIPMENT FAILURE
Subcause—

Casualties

Fatalities0
Injuries0

Costs

Property Damage
Lost Commodity
Public/Private Damage
Emergency Response
Environmental Remediation
Other Costs

Location Map

Incident Narrative

ON JUNE 25, 2019 AT 5:44 PM, HOUSTON CONTROL CENTER CONTROLLER ACKNOWLEDGED AN ALARM OF A LEAK AT THREE RIVERS PUMP STATION AND DISPATCHED NGL TECHNICIAN TO THE SITE. CONTROLLER TOOK PUMP STATION OFF LINE AT 6:05 PM. THE LEAK OCCURRED BETWEEN THE 90 AND THE FERRULE ON THE 3/8"" STAINLESS STEEL TUBING ON PIT 302 ON PUMP 300 (PUMP #2). NGL TECH ARRIVED AT 6:45 P.M. AND NOTICED A CRACK/FRACTURE IN THE TUBING. THE PUMP WAS OFFLINE WHILE THE TUBING WAS REPAIRED. THE THREE RIVERS PUMP STATION WAS BACK ONLINE AT 9:31 P.M. METALLURGICAL ANALYSIS REVEALED FATIGUE STRIATIONS THROUGHOUT THE FRACTURE SURFACE. THE CRACK WAS PROPAGATED BY REPETITIVE FATIGUE (VIBRATION). NO MATERIAL DEFECTS WERE FOUND. TEXAS RRC WAS TELEPHONICALLY NOTIFIED ON 6-25-19 AT 7:34 P.M. BY JOHN PONTIOUS. RRC INCIDENT NUMBER IS 2017.