TARGA DOWNSTREAM LLC

hazardous_liquid Incident — — July 30, 2019

Incident Information

Incident DateJuly 30, 2019
OperatorTARGA DOWNSTREAM LLC
CommodityHVL OR OTHER FLAMMABLE OR TOXIC FLUID WHICH IS A GAS AT AMBI
Pipeline Typehazardous_liquid

Location

State
Coordinates32.77773, -97.64054

Cause

CauseEQUIPMENT FAILURE
SubcauseFAILURE OF EQUIPMENT BODY (EXCEPT PUMP), TANK PLATE, OR OTHER MATERIAL

Casualties

Fatalities0
Injuries0

Costs

Property Damage$270,000
Emergency Response$5,000
Other Costs$300,000

Location Map

Incident Narrative

A PINHOLE LEAK WAS DISCOVERED IN THE VALVE BODY OF A 20"" BLOCK VALVE AT TARGA'S WEATHERFORD STATION. THE LEAK WAS SO SMALL THE EMPLOYEE HAD TO USE SNOOP LIQUID SOAP TO PIN POINT IT. THE COST OF PIGGING THE PRODUCT OUT OF THIS SEGMENT OF PIPELINE AND EQUIPMENT TO REMOVE AND REPLACE THE VALVE IS WHAT MADE THIS A REPORTABLE ACCIDENT, NOT THE AMOUNT OF PRODUCT LOST. AFTER THE VALVE WAS REMOVED, USING DYE PENETRANT, A SMALL CRACK INSIDE OF THE VALVE BODY WAS FOUND THAT ALLOW PRODUCT TO FIND IT'S WAY TO THE PIN HOLE ON THE OUTSIDE OF THE VALVE BODY AND LEAK TO THE ATMOSPHERE.

About This Pipeline Incident

Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.

Back to All Incidents More Incidents in