"WINK TO WEBSTER PIPELINE, LLC"

hazardous_liquid Incident — — June 10, 2021

Incident Information

Incident DateJune 10, 2021
Operator"WINK TO WEBSTER PIPELINE, LLC"
CommodityCRUDE OIL
Pipeline Typehazardous_liquid

Location

State
Coordinates29.61211, -95.18608

Cause

CauseEQUIPMENT FAILURE
SubcauseOTHER EQUIPMENT FAILURE

Casualties

Fatalities0
Injuries0

Costs

Property Damage$0
Emergency Response$0
Other Costs$0

Location Map

Incident Narrative

"ON THE MORNING OF FRIDAY, JUNE 10, EXXONMOBIL PIPELINE CO. (EMPCO) WAS NOTIFIED BY A THIRD PARTY OPERATOR OF A SPILL AT THE WINK TO WEBSTER ECHO STATION AT 0709. UPON NOTICE, EMPCO SHUT DOWN AND ISOLATED THE STATION AT 0712. EMPCO PERSONNEL ARRIVED ONSITE AT 7:45 AND CONFIRMED A REPORTABLE VOLUME AT 0750. THE SOURCE OF THE SPILL WAS ISOLATED, MITIGATED AND THE SITE WAS CLEANED UP. THE CAUSE WAS DETERMINED TO BE A 3/4 INCH MANIFOLD VALVE CONNECTED TO A PRESSURE GAUGE THAT EXPERIENCED EXCESSIVE VIBRATION DURING START UP OF THE FACILITY. A BLEEDER VALVE ON THE MANIFOLD VALVE LOOSENED AS A RESULT OF THE VIBRATION WHICH RESULTED IN THE SPILL. THE PRESSURE GAUGE AND ASSOCIATED VALVE WAS REMOVED AND PLUGGED. EMPCO IDENTIFIED OTHER LOCATIONS WHERE SIMILAR VALVES ARE INSTALLED AND EMPCO IS REPLACING OR PLUGGING THE SIMILAR MANIFOLD VALVES. (PLEASE NOTE: EXXONMOBIL PIPELINE COMPANY IS THE CONTRACTUAL SERVICE PROVIDER FOR WINK TO WEBSTER PIPELINE, LLC)"

About This Pipeline Incident

Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.

Back to All Incidents More Incidents in