JAYHAWK PIPELINE LLC

hazardous_liquid Incident — — January 14, 2020

Incident Information

Incident DateJanuary 14, 2020
OperatorJAYHAWK PIPELINE LLC
CommodityCRUDE OIL
Pipeline Typehazardous_liquid

Location

State
Coordinates37.13986, -100.56936

Cause

CauseEQUIPMENT FAILURE
SubcausePUMP OR PUMP-RELATED EQUIPMENT

Casualties

Fatalities0
Injuries0

Costs

Property Damage$10,000
Emergency Response$10,000
Other Costs$500

Location Map

Incident Narrative

AT 10:20 PM CST, THE CONTROLLER NOTICED THAT THE MEADE BOOSTER PUMP BP-3201 DID NOT APPEAR TO BE PUTTING UP ENOUGH PRESSURE AND FLOW TO BE FUNCTIONING PROPERLY. THE CONTROLLER SHUT DOWN THE PUMP, ATTEMPTED ONE RESTART, PER JAYHAWK PIPELINE PROCEDURES, AND IMMEDIATELY SHUT THE PUMP BACK DOWN/ISOLATED IT FROM THE SYSTEM. THE CONTROLLER NOTIFIED APPROPRIATE PERSONNEL AND MOBILIZED FIELD STAFF TO THE PUMP STATION TO INVESTIGATE. UPON ARRIVAL AT THE PUMP STATION, FIELD STAFF CONFIRMED THAT THE PUMP SEAL FAILED AND HAD RELEASED APPROXIMATELY 4.6 BARRELS OF PRODUCT TO THE TANK DIKE. 100% OF THE PRODUCT WAS CONTAINED ON THE OPERATOR CONTROLLED PROPERTY. THE PUMP WAS REPLACED AND THE SYSTEM RETURNED TO SERVICE THE FOLLOWING DAY. KDHE WAS NOTIFIED OF THE INCIDENT. THE NRC REPORTING THRESHOLDS WERE NOT MET AS A RESULT OF THIS INCIDENT.