KINDER MORGAN LIQUID TERMINALS, LLC

hazardous_liquid Incident —

Incident Information

Report Date
OperatorKINDER MORGAN LIQUID TERMINALS, LLC
Commodity—
Pipeline Typehazardous_liquid

Location

State
Coordinates29.73166, -95.19928

Cause

CauseEQUIPMENT FAILURE
Subcause—

Casualties

Fatalities0
Injuries0

Costs

Property Damage
Lost Commodity
Public/Private Damage
Emergency Response
Environmental Remediation
Other Costs

Location Map

Incident Narrative

ON APRIL 8, 2020, AN OPERATOR DISCOVERED PRODUCT COMING FROM A THREADED PIPE CONNECTION ON THE PRV PIPING NEAR THE TCR PUMP. THE PRODUCT WAS CLEANED UP AND THE CRACKED PIPE NIPPLE WAS REPLACED. DURING THE INVESTIGATION, IT WAS DISCOVERED THAT THE PIPE NIPPLE CRACKED DUE TO STRESS ON THE PIPE CAUSED BY IMPROPER SUPPORT. PLAN TO PREVENT RECURRENCE: ADDITIONAL SUPPORT HAS BEEN ADDED AND PIPING MODIFICATIONS HAVE BEEN MADE TO REDUCE THE VIBRATION OF THE PIPING NEAR THE PUMP.