ONEOK NGL PIPELINE, LLC
hazardous_liquid Incident —
Incident Information
| Report Date | — |
| Operator | ONEOK NGL PIPELINE, LLC |
| Commodity | — |
| Pipeline Type | hazardous_liquid |
Location
| State | |
| Coordinates | 31.43558, -94.76016 |
Cause
| Cause | EQUIPMENT FAILURE |
| Subcause | — |
Casualties
| Fatalities | 0 |
| Injuries | 0 |
Costs
| Property Damage | — |
| Lost Commodity | — |
| Public/Private Damage | — |
| Emergency Response | — |
| Environmental Remediation | — |
| Other Costs | — |
Location Map
Incident Narrative
ON MAY 13TH AT APPROXIMATELY 3:50 PM, AT THE ONEOK LUFKIN PUMP STATION, A SEAL FAIL WAS IDENTIFIED ON THE OB SEAL OF PUMP #2. THE OPERATOR ISOLATED AND FLARED DOWN THE PUMP AND MADE ALL INTERNAL NOTIFICATIONS AS REQUIRED. THE SEAL AND RELATED COMPONENTS WERE REPLACED AND THE PUMP WAS PLACED BACK IN SERVICE. THE FAILED SEAL WAS SENT TO THE MANUFACTURER FOR FAILURE ANALYSIS WHICH REVEALED THE FAILURE OF THE SEAL WAS CAUSED BY THE EXCESSIVE AMOUNT OF AXIAL THRUST, WHICH WAS DUE TO THE THRUST BEARING RETAINER ANTI-ROTATION TAB BEING WORN DOWN. THIS SPINNING OF THE THRUST BEARING'S OUTER RACE ALLOWED THE THRUST END PLATE TO WEAR RAPIDLY UNTIL THE OVERALL THRUST OF THE PUMP CAUSED THE FAILURE.
About This Pipeline Incident
Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.