ENTERPRISE CRUDE PIPELINE LLC

hazardous_liquid Incident —

Incident Information

Report Date
OperatorENTERPRISE CRUDE PIPELINE LLC
Commodity—
Pipeline Typehazardous_liquid

Location

State
Coordinates31.54283, -103.51962

Cause

CauseCORROSION FAILURE
Subcause—

Casualties

Fatalities0
Injuries0

Costs

Property Damage
Lost Commodity
Public/Private Damage
Emergency Response
Environmental Remediation
Other Costs

Location Map

Incident Narrative

AT 4:56 PM ON 6/30/2020 AERIAL PATROL REPORTED POTENTIAL CRUDE ON THE ROW. AT APPROXIMATELY 7:45 AM ON 7/1/20, A TECHNICIAN CONFIRMED CRUDE RELEASED ON LID C105, AND PIPELINE WAS IMMEDIATELY SHUT DOWN. AT 9:10 AM, IT WAS ESTIMATED THE AMOUNT OF CRUDE EXCEEDED 5 GALLONS AND THE TRRC WAS NOTIFIED OF THE ACCIDENT. THE PIPELINE WAS EXCAVATED, VISUALLY EXAMINED, AND A CLAMP WAS INSTALLED. THERE WAS NO FREE LIQUID AVAILABLE FOR RECOVERY. IN CONSIDERATION THAT THE COMMODITY WAS BEING TREATED WITH CORROSION INHIBITOR, BIOCIDE AND PARAFFIN SOLVENT, CLEANING PIGS AND CORROSION COUPONS WERE ROUTINELY UTILIZED, AND THE SIX O'CLOCK ORIENTATION OF THE PIN-HOLE LEAK, INTERNAL UNDER-DEPOSIT CORROSION IS A POSSIBLE CAUSE BUT WAS NOT VISUALLY VERIFIED BY CUTTING OPEN THE PIPELINE. TO PREVENT A RECURRENCE, THE FOLLOWING ACTIONS WILL BE IMPLEMENTED: - A MORE AGGRESSIVE CLEANING PIG WILL BE UTILIZED; - THE PIGGING FREQUENCY WILL BE INCREASED; - THE INTERNAL CORROSION PREVENTION CHEMICAL APPLICATION WILL BE CHANGED FROM CONTINUOUSLY INJECTED TO A BATCH TREATMENT DURING PIGGING FORMAT; - CONTINUED MONITORING OF INTERNAL CORROSION RATES UTILIZING WEIGHT LOSS COUPONS; AND - INITIATE ROUTINE TESTS FOR MICROBIOLOGICALLY INFLUENCED CORROSION (MIC). THE TRRC WAS NOTIFIED AT 9:17 AM, AND INCIDENT # IS 2231.

About This Pipeline Incident

Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.

Back to All Incidents More Incidents in