ENBRIDGE STORAGE (CUSHING) L.L.C.
hazardous_liquid Incident — — August 7, 2020
Incident Information
| Incident Date | August 7, 2020 |
| Operator | ENBRIDGE STORAGE (CUSHING) L.L.C. |
| Commodity | CRUDE OIL |
| Pipeline Type | hazardous_liquid |
Location
| State | |
| Coordinates | 35.95886, -96.75335 |
Cause
| Cause | CORROSION FAILURE |
| Subcause | INTERNAL CORROSION |
Casualties
| Fatalities | 0 |
| Injuries | 0 |
Costs
| Property Damage | $6,000 |
| Emergency Response | $22,000 |
| Other Costs | $0 |
Location Map
Incident Narrative
ON AUGUST 7, 2020 AT APPROXIMATELY 6:44 AM CDT OPERATIONS TECHNICIANS DISCOVERED CRUDE OIL SEEPING UP NEAR VALVES 206-B-301 AND 206-B-302 IN MANIFOLD 206 WITHIN THE CUSHING NORTH TERMINAL. AFTER HYDRO EXCAVATION THE SOURCE WAS DETERMINED TO BE A PINHOLE IN THE HEAT AFFECTED ZONE ON THE FLANGE SIDE OF THE WELD BETWEEN THE TEE FITTING AND FLANGE CONNECTED TO VALVE 206-B-301. THE AFFECTED TEE FITTING WAS REMOVED AND BLINDS WERE INSTALLED. THIS SECTION OF PIPE HAS BEEN IDLE SINCE IT WAS REPLACED WITH A NEW MANIFOLD. APPROXIMATELY 1 BARREL OF OIL WAS RELEASED. ALL FREE OIL WAS RECOVERED AND CONTAMINATED SOILS REMOVED. A METALLURGICAL ANALYSIS WAS COMPLETED AND IDENTIFIED INTERNAL CORROSION ON THE TEE AS THE CAUSE OF THE PINHOLE RELEASE.
About This Pipeline Incident