CENTRAL FLORIDA PIPELINE CORP

hazardous_liquid Incident —

Incident Information

Report Date
OperatorCENTRAL FLORIDA PIPELINE CORP
Commodity—
Pipeline Typehazardous_liquid

Location

State
Coordinates27.93864, -82.43784

Cause

CauseINCORRECT OPERATION
Subcause—

Casualties

Fatalities0
Injuries0

Costs

Property Damage
Lost Commodity
Public/Private Damage
Emergency Response
Environmental Remediation
Other Costs

Location Map

Incident Narrative

WHILE INSTALLING CFF PUMP H3 AT HEMLOCK STATION, LOCAL OPERATIONS WAS APPLYING PRESSURIZED PRODUCT TO THE PUMP IN AN EFFORT TO COMPLETE THE REFILLING PROCESS AND PERFORM A LEAK CHECK OF THE PUMP. A RELEASE OF PRODUCT OCCURRED WHEN AN UNNOTICED TEMPORARY PLUG BLEW OUT OF A PORT, LOCATED ON THE SIDE OF THE PUMPS SUCTION SIDE FLANGE. (10/22/20 UPDATE): NEW COST INFORMATION RECEIVED ON 10/15 DROVE PROJECTED COSTS ASSOCIATED WITH THIS RELEASE OVER THE NRC REPORTABILITY THRESHOLD OF $50,000. A REPORT WAS MADE TO THE NRC AS REQUIRED. THE INCIDENT INVESTIGATION CONCLUDED THE TEMPORARY PLUG THAT BLEW OUT AND CAUSED THIS RELEASE WAS MADE OF PLASTIC AND INSTALLED BY A THIRD PARTY PUMP MANUFACTURER AS PART OF THEIR WORK TO REFURBISH PUMP H3. THE TEMPORARY PLASTIC PLUG'S PRESENCE WAS NOT READILY APPARENT, LIKELY BECAUSE IT WAS PAINTED OVER. THE PUMP'S REINSTALLATION WORK PLAN DID NOT INCLUDE LANGUAGE TO VERIFY THE TIGHTNESS OF ALL COMPONENTS.