DTE GAS COMPANY

gas_distribution Incident — GROSSE POINTE SHORES, MI — March 28, 2025

Incident Information

Incident DateMarch 28, 2025
OperatorDTE GAS COMPANY
CommodityNATURAL GAS
Pipeline Typegas_distribution

Location

CityGROSSE POINTE SHORES
StateMI
CountyWAYNE COUNTY
Coordinates42.43223, -82.88069

Cause

CauseOTHER INCIDENT CAUSE
SubcauseUNKNOWN

Casualties

Fatalities0
Injuries0

Costs

Property Damage$8,357
Emergency Response$0
Other Costs$0

Location Map

Incident Narrative

"GAS LEAK CALLED IN BY CUSTOMER FOR SINGLE FAMILY RESIDENCE AT 08:12AM ON 3/28/25. DTE GAS TECHNICIAN ARRIVED AT 08:45AM AND DISCOVERED 3 LEAKS AT METER MANIFOLD. ONE LEAK FOUND AT REGULATOR BODY SCREW, WAS TIGHTENED AND LEAK STOPPED. SECOND LEAK WAS ABOVE SHUT-OFF VALVE ON INSULATED UNION. GAS TO RESIDENCE WAS SHUT OFF VIA LOCKWING VALVE. A THIRD LEAK WAS BELOW THE SHUT-OFF VALVE. AT 8:50, TECHNICIAN WENT TO VEHICLE TO CALL FOR A DISTRIBUTION CREW TO CUT THE SERVICE. AT APPROXIMATELY 08:57, GAS IGNITED AND 911 WAS CALLED. TECHNICIAN WAS AT VEHICLE IN DRIVEWAY AT TIME OF IGNITION, WHICH WAS VERIFIED VIA HOME SECURITY VIDEO FOOTAGE. CAUSE OF IGNITION IS UNKNOWN. RESIDENCE CAUGHT FIRE AND IS A TOTAL LOSS. SERVICE IS 1-1/4"" MDPE PIPE OPERATING AT 57PSIG WITH MAOP 60PSIG INSTALLED IN 2005. GAS WAS SHUT OFF VIA PINCH-OFF AT 11:50AM. LEAK CHECKS FOUND NO GAS IN THE GROUND AND ODORANT LEVELS ADEQUATE. LOST GAS CALCULATED TO BE 129 MCF. NO INJURIES OR FATALITIES."

About This Pipeline Incident

Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.

Back to All Incidents More Incidents in MI