KINDER MORGAN LIQUID TERMINALS, LLC

hazardous_liquid Incident —

Incident Information

Report Date
OperatorKINDER MORGAN LIQUID TERMINALS, LLC
Commodity—
Pipeline Typehazardous_liquid

Location

State
Coordinates29.73320, -95.20237

Cause

CauseEQUIPMENT FAILURE
Subcause—

Casualties

Fatalities0
Injuries0

Costs

Property Damage
Lost Commodity
Public/Private Damage
Emergency Response
Environmental Remediation
Other Costs

Location Map

Incident Narrative

ON SEPTEMBER 3, 2020 AT 14:30, 2.1 BARRELS OF PRODUCT WAS DISCOVERED NEAR THE E-VALVE OF TANK 150-65. THE PRODUCT WAS CLEANED UP IMMEDIATELY. THE SOURCE OF THE LEAK WAS IDENTIFIED AS A BURIED FLANGE NEAR THE E-VALVE. THE BOLTS ON THE FLANGE WERE TORQUED AND THE LEAK STOPPED. THE INCIDENT INVESTIGATION SHOWED THE LIKELY CAUSE OF THE LOOSE BOLTS WAS DUE TO THERMAL PRESSURE. THE LINE HAS PRESSURE RELIEF VALVE. TANK 150-65 WAS OUT OF SERVICE FOR API 653 AND RETURNED TO SERVICE IN MARCH 2020. THE THERMAL FOR THE TANK-LINES WERE ROUTED TO TANK 150-66. THE THERMAL LINE THAT LEAKED WAS NOT REROUTED TO 150-65 UNTIL 18 SEPTEMBER 2020 (13 DAYS AFTER INCIDENT). THE GASKET WAS REPLACED OUT OF AN ABUNDANCE OF CAUTION. PLAN FOR PREVENTION: THE FLANGE WILL REMAIN EXPOSED AND NOT REBURIED. ON A GO FORWARD BASIS, THE THERMAL RELIEF SYSTEM WILL BE REVIEWED AS THE TANKS IS RETURNED TO SERVICE USING THE MANWAY REMOVAL FORM.

About This Pipeline Incident

Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.

Back to All Incidents More Incidents in