DCP MIDSTREAM

hazardous_liquid Incident —

Incident Information

Report Date
OperatorDCP MIDSTREAM
Commodity—
Pipeline Typehazardous_liquid

Location

State
Coordinates32.96784, -97.94222

Cause

CauseMATERIAL FAILURE OF PIPE OR WELD
Subcause—

Casualties

Fatalities0
Injuries0

Costs

Property Damage
Lost Commodity
Public/Private Damage
Emergency Response
Environmental Remediation
Other Costs

Location Map

Incident Narrative

ON SEPTEMBER 3RD, 2020 A SMALL PIN HOLE LEAK WAS DISCOVERED ON SOUTHERN HILLS PIPELINE AFTER DIG NUMBER SOHI.S6.015952.T19.D20.N.P3 WAS EXCAVATED FOR EXAMINATION. LEAK SITE LOCATION WAS BETWEEN MLV 39 AND MLV 40 ON THE SOUTHERN HILLS SYSTEM. LEAK SITE WAS ONLY DETECTABLE WITH A 4-GAS DETECTOR WITHIN ONE INCH FROM THE SMALL PIN HOLE. EXCAVATION CREW EXITED DITCH AND MADE NOTIFICATION TO OPS AND INTEGRITY GROUPS IMMEDIATELY. DIG SITE WAS CAUTION TAPED OFF AND CONTINUOUSLY MONITORED FOR ANY INCREASED VAPORS AND NONE WAS FOUND. A PLIDCO 18 INCH X 18 INCH CLAMP WAS INSTALLED AS TEMPORARY REPAIR UNTIL A CUSTOM PLIDCO SLEEVE 18 INCH X 36 INCH IS ONSITE FOR THE PERMANENT REPAIR. THE CUSTOM CLAMP WAS ORDERED AND WILL BE ON SITE MID-NOVEMBER AND AT THAT TIME WILL BE INSTALLED PER MANUFACTURE'S RECOMMENDATION FOR A PERMANENT REPAIR.