EXPRESS HOLDINGS (USA), LLC

hazardous_liquid Incident — — September 28, 2020

Incident Information

Incident DateSeptember 28, 2020
OperatorEXPRESS HOLDINGS (USA), LLC
CommodityCRUDE OIL
Pipeline Typehazardous_liquid

Location

State
Coordinates42.75098, -105.61374

Cause

CauseEQUIPMENT FAILURE
SubcauseTHREADED CONNECTION/COUPLING FAILURE

Casualties

Fatalities0
Injuries0

Costs

Property Damage$1,012
Emergency Response$1,640
Other Costs$0

Location Map

Incident Narrative

ON SEPTEMBER 28, 2020 AT 13:35 MDT A TECHNICIAN DISCOVERED OIL ON THE PUMP BUILDING FLOOR AROUND THE MP2 PUMP AT THE DOUGLAS STATION DURING A VISUAL STATION CHECK. ALL FREE OIL WAS CONTAINED WITHIN THE PUMP BUILDING AND WAS APPROXIMATELY 15 GALLONS. THE PUMP WAS SHUTDOWN AND LOCKED OUT TO PREVENT FURTHER RELEASE. THE OIL WAS PROMPTLY CLEANED UP AND PROPERLY DISPOSED OF. THE SOURCE OF THE LEAK WAS FROM A 1"" THREADED CONNECTION AT THE TOP OF THE PUMP CASE ON THE OUTBOARD SIDE. THE 1"" CONNECTION IS PART OF THE BALANCE LINE FROM THE OUTBOARD TO INBOARD SIDE OF THE PUMP. THE PUMP WILL REMAIN LOCKED OUT UNTIL REPAIRS CAN BE MADE. AN INVESTIGATION TO DETERMINE IF A BETTER BALANCE LINE DESIGN IS FEASIBLE WILL BE AT A LATER DATE.