PLAINS PIPELINE, L.P.
hazardous_liquid Incident —
Incident Information
| Report Date | — |
| Operator | PLAINS PIPELINE, L.P. |
| Commodity | — |
| Pipeline Type | hazardous_liquid |
Location
| State | |
| Coordinates | 32.26313, -104.13299 |
Cause
| Cause | EQUIPMENT FAILURE |
| Subcause | — |
Casualties
| Fatalities | 0 |
| Injuries | 0 |
Costs
| Property Damage | — |
| Lost Commodity | — |
| Public/Private Damage | — |
| Emergency Response | — |
| Environmental Remediation | — |
| Other Costs | — |
Location Map
Incident Narrative
APPROXIMATELY 3.75 BARRELS OF CRUDE OIL WERE RELEASED FROM PUMP 1010 AT MATADOR RUSTLER STATION. THE DATE AND TIME OF THE RELEASE (PART A Q4) IS INDICATIVE OF THE EARLIEST POSSIBLE TIME THE RELEASE COULD HAVE STARTED, AS IT WAS THE LAST TIME THE STATION HAD BEEN VISITED AND CONFIRMED CRUDE OIL WAS NOT BEING RELEASED. THE CAUSE OF THE INCIDENT WAS DETERMINED TO BE EQUIPMENT FAILURE OF THE BELLOW IN THE PRESSURE SAFETY VALVE (PSV) DUE TO NORMAL WEAR AND TEAR FROM PULSATION OF THE PD PUMP. TO PREVENT FUTURE RELEASES, PLAINS REPLACED THE PSV, AND IS FURTHER INVESTIGATING MANNERS OF PREVENTING REOCCURRENCE, SUCH AS REPLACING THE PSV WITH A MODEL THAT DOESN'T HAVE A BELLOW, OR RECONFIGURING THE DESIGN OF THE PUMP.