KINDER MORGAN LIQUID TERMINALS, LLC

hazardous_liquid Incident —

Incident Information

Report Date
OperatorKINDER MORGAN LIQUID TERMINALS, LLC
Commodity—
Pipeline Typehazardous_liquid

Location

State
Coordinates29.73321, -95.20236

Cause

CauseCORROSION FAILURE
Subcause—

Casualties

Fatalities0
Injuries0

Costs

Property Damage
Lost Commodity
Public/Private Damage
Emergency Response
Environmental Remediation
Other Costs

Location Map

Incident Narrative

AT APPROX. 16:00 ON NOV 10TH, 2020 A KM OPERATOR DISCOVERED AN ESTIMATED ONE BARREL OF CRUDE CONDENSATE NEAR TANK 150-65. ON NOVEMBER 13TH THE SOURCE OF THE LEAK WAS DETERMINED TO BE TANK 150-65 TANK STRIPPER LINE WHICH IS JURISDICTIONAL AND THE VOLUME WAS DETERMINED TO BE GREATER THAN 5 GALLONS - THE TOTAL WAS 1BBL.. HYDRO-EXCAVATION REVEALED A SMALL PINHOLE LEAK ON THE 6"" LINE. THE LINE WAS ISOLATED AND HAS BEEN REMOVED AND REPLACED WITH AN ABOVE GROUND LINE REMOVING THE LOW SPOT IN THE LINE. METALLURGICAL ANALYSIS SHOWED MIC PRESENT. PLAN FOR PREVENTION: TWICE PER YEAR THE LINE WILL BE FLUSHED.

About This Pipeline Incident

Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.

Back to All Incidents More Incidents in