SFPP, LP

hazardous_liquid Incident —

Incident Information

Report Date
OperatorSFPP, LP
Commodity—
Pipeline Typehazardous_liquid

Location

State
Coordinates33.84549, -118.23015

Cause

CauseEQUIPMENT FAILURE
Subcause—

Casualties

Fatalities0
Injuries0

Costs

Property Damage
Lost Commodity
Public/Private Damage
Emergency Response
Environmental Remediation
Other Costs

Location Map

Incident Narrative

ON 4/1/2021 AT 05:30 AM, AN OPERATOR AT WATSON DISCOVERED PRODUCT SURROUNDING THE ENTIRE TANK CHIME ON TANK W-2. UPON FURTHER INVESTIGATION, THE OPERATOR THEN DISCOVERED PRODUCT IN THE TANK'S VALVE VAULT. UPDATE 8/16/21: CRACKS FOUND IN THE SHELL-TO-BOTTOM WELD. THE CRACKS WERE CAUSED BY AN INADEQUATE DESIGN OF THE SUMP BEING PLACED TOO CLOSE TO THE TANK SHELL. THIS SUMP PLACEMENT CREATED STRESSES CAUSING CRACKING IN THE SHELL-TO-BOTTOM WELD. TO PREVENT REOCCURRENCE OF CRACKING, THE NEW SUMP WILL BE INSTALLED FURTHER AWAY FROM THE TANK SHELL, INSTALL A BUTT-WELDED ANNULAR RING AND INSTALL A THICKER PLATE.