MAGELLAN PIPELINE COMPANY, LP

hazardous_liquid Incident —

Incident Information

Report Date
OperatorMAGELLAN PIPELINE COMPANY, LP
Commodity—
Pipeline Typehazardous_liquid

Location

State
Coordinates45.02601, -93.20275

Cause

CauseEQUIPMENT FAILURE
Subcause—

Casualties

Fatalities0
Injuries0

Costs

Property Damage
Lost Commodity
Public/Private Damage
Emergency Response
Environmental Remediation
Other Costs

Location Map

Incident Narrative

AT 1:30 ON JUNE 16, 2021, A SEAL LEAK DETECTION ALARM WAS ACTIVATED AT MAGELLAN'S MINNEAPOLIS TERMINAL. UPON ACTIVATION OF THE ALARM, THE PUMP SHUTDOWN. MAGELLAN PERSONNEL ISOLATED THE PUMP AND CLEANUP ACTIVITIES WERE INITIATED. THE PUMP WAS SENT IN FOR FAILURE ANALYSIS AND IT WAS DETERMINED THAT THE INNER BEARING FAILED DUE TO PIPE STRAIN WHICH ALLOWED THE SEAL FACES TO SEPARATE AND FOR PRODUCT TO LEAK. PIPE SUPPORTS HAVE BEEN ADDED TO ALLEVIATE FUTURE STRAIN AND A NEW PUMP HAS BEEN INSTALLED. SUPPLEMENTAL/FINAL (11-12-2021) CORRECTION: PART E1

About This Pipeline Incident

Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.