WILLIAMS OLEFINS FEEDSTOCK PIPELINES, LLC

hazardous_liquid Incident — — September 2, 2021

Incident Information

Incident DateSeptember 2, 2021
OperatorWILLIAMS OLEFINS FEEDSTOCK PIPELINES, LLC
CommodityHVL OR OTHER FLAMMABLE OR TOXIC FLUID WHICH IS A GAS AT AMBI
Pipeline Typehazardous_liquid

Location

State
Coordinates30.28989, -93.03822

Cause

CauseEQUIPMENT FAILURE
SubcausePUMP OR PUMP-RELATED EQUIPMENT

Casualties

Fatalities0
Injuries0

Costs

Property Damage$0
Emergency Response$0
Other Costs$0

Location Map

Incident Narrative

RECEIVED A GAS DETECTION ALARM AT 4:08 AM, THAT A GAS DETECTOR HAD ALARMED AT CALCASIEU PUMP STATION. UPON ARRIVAL AT 16:00, IT WAS NOTICED THAT THE PUMP SEAL WAS LEAKING AND CAUSING THE GAS DETECTOR TO ALARM. CLEARED ALARMS AND HAD PIPELINE CONTROL START THE PUMP TO CLEAR SEAL FACES. WILLIAMS HAS CONTACTED THE SEAL MANUFACTURER TO HAVE A SEAL AND SEAL FLUSH RE-DESIGN. IN THE INTERIM, THE SEAL FAIL SWITCHES HAVE BEEN LOWERED TO HELP WITH IDENTIFYING ANY SUBSEQUENT RELEASES IN A MORE TIMELY MANNER. WILLIAMS HAS ISOLATED THE PUMP STATION AND DE-INVENTORIED THE PUMP PIPING TO PREVENT THIS ISSUE FROM HAPPENING AGAIN.