ALON USA, LP

hazardous_liquid Incident —

Incident Information

Report Date
OperatorALON USA, LP
Commodity—
Pipeline Typehazardous_liquid

Location

State
Coordinates32.49814, -98.77996

Cause

CauseCORROSION FAILURE
Subcause—

Casualties

Fatalities0
Injuries0

Costs

Property Damage
Lost Commodity
Public/Private Damage
Emergency Response
Environmental Remediation
Other Costs

Location Map

Incident Narrative

THE PIPELINE WAS IN THE PROCESS OF BEING PERMANENTLY DECOMMISSIONED. AS PART OF THE DECOMMISSIONING PLAN, NITROGEN WAS RE-INTRODUCED. THE PIPELINE HAD BEEN REPRESENTED AS FILLED WITH NITROGEN WHEN ACQUIRED FROM THE PREVIOUS OPERATOR. A NITROGEN PRESSURE DROP WAS DETECTED ON THE LINE, AND THE DECOMMISSIONING ACTIVITIES WERE STOPPED. GROUND PATROLS WERE COMMENCED TO WALK THE LINE FROM THE PIG'S LAST KNOWN LOCATION. FURTHER INVESTIGATION REVEALED A RELEASE OF AGED GASOLINE MATERIAL INITIALLY IN THE GENERAL AREA OF EASTLAND, TX. AGENCY NOTIFICATIONS WERE MADE AND SPILL RESPONSE ACTIVITIES WERE COMMENCED AT THE SITE. CAUSE OF FAILURE WAS DETERMINED TO BE EXTERNAL CORROSION DUE TO EXPOSURE TO BRACKISH WATER CONTAINING CO2. ADDITIONAL EVIDENCE OF POTENTIAL INTERFERENCE FROM BURIED METALLIC PIPE WAS IDENTIFIED DURING EXCAVATION OF THE SITE.