DCOR, LLC

hazardous_liquid Incident —

Incident Information

Report Date
OperatorDCOR, LLC
Commodity—
Pipeline Typehazardous_liquid

Location

State
Coordinates33.68472, -118.06308

Cause

CauseCORROSION FAILURE
Subcause—

Casualties

Fatalities0
Injuries0

Costs

Property Damage
Lost Commodity
Public/Private Damage
Emergency Response
Environmental Remediation
Other Costs

Location Map

Incident Narrative

DATE 1/2/22 OES REPORT #22-0017 NRC REPORT #1325728 ON 12/22/2021, THE OEC WAS NOTIFIED OF A POTENTIAL RELEASE OF CRUDE OIL EMANATING FROM PIPELINE #0919. THE TRANSFER PIPELINE EXTENDS FROM PLATFORM EVA TO THE FORT APACHE ONSHORE SEPARATION FACILITY. AS A PRECAUTION, THE PIPELINE WAS SHUT IN AND AN OIL SPILL RESPONSE ORGANIZATION (OSRO) NOTIFIED. SINCE THAT TIME, A UNIFIED COMMAND WAS ASSEMBLED CONSISTING OF OSRO, CALIFORNIA DEPARTMENT OF FORESTRY AND FIRE PROTECTION (CAL FIRE), U.S. COAST GUARD (USCG), CALIFORNIA STATE LANDS COMMISSION (SLC), AND THE CALIFORNIA DEPARTMENT OF FISH & WILDLIFE'S (CDFW) OFFICE OF SPILL PREVENTION AND RESPONSE (OSPR). ON 1/2/22 A COORDINATED EFFORT TO LOCATE THE SOURCE OF THE RELEASE WAS PUT INTO OPERATION. THE PLAN INCLUDED PUSHING SEAWATER THROUGH THE LINE TO EVACUATE THE REMAINING OIL IN THE LINE. SAFETY MEASURES WERE PUT IN PLACE PRIOR TO COMMENCEMENT OF THE OPERATION TO INCLUDE AERIAL OBSERVATION AND ON-SITE VESSELS (BOOMS AND SKIMMERS). DURING THE OPERATION, A HELICOPTER CREW OBSERVED A SHEEN ON THE SURFACE OF THE OCEAN AND THE PUMPING WAS STOPPED. THE SHEEN WAS IMMEDIATELY CONTAINED WITHIN A BOOM AND A CLEANUP OPERATION INITIATED. FURTHER ACTIONS TO IDENTIFY THE SOURCE WERE ALSO INITIATED. FIELD EXAMINATION FOUND A PINHOLE LEAK AT THE 6 O'CLOCK POSITION WHICH INDICATED SUSPECTED MICROBIOLOGICAL INDUCED CORROSION. SUBSEQUENT PIPE CLAMP REPAIR AND HYDROTEST OF PIPELINE HAS BEEN COMPLETED. FURTHER PIPELINE DIAGNOSTICS WERE PERFORMED UTILIZING XYZ/GEOMETRY SMART PIG AND UT SMART PIG.

About This Pipeline Incident

Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.

Back to All Incidents More Incidents in