ENTERPRISE PRODUCTS OPERATING LLC

hazardous_liquid Incident —

Incident Information

Report Date
OperatorENTERPRISE PRODUCTS OPERATING LLC
Commodity—
Pipeline Typehazardous_liquid

Location

State
Coordinates32.10479, -99.22786

Cause

CauseEQUIPMENT FAILURE
Subcause—

Casualties

Fatalities0
Injuries0

Costs

Property Damage
Lost Commodity
Public/Private Damage
Emergency Response
Environmental Remediation
Other Costs

Location Map

Incident Narrative

ON 7/17/2022 AT 17:28 CDT, SHIN OAK PIPELINE CROSS PLAINS STATION SHUT DOWN DUE TO A HAZARDOUS GAS ALARM. A TECHNICIAN RESPONDED TO THE SITE AND CONFIRMED THE RELEASE AT 18:57. ON PUMP #2 DISCHARGE, 1/2"" TUBING CONNECTED TO A 1"" VALVE WITH A REDUCER SNAPPED INTO TWO FRAGMENTS. THE PUMP WAS ISOLATED AND BLOWN DOWN, AND THE TUBING WAS REPLACED.