DIXIE PIPELINE COMPANY LLC

hazardous_liquid Incident — — September 26, 2024

Incident Information

Incident DateSeptember 26, 2024
OperatorDIXIE PIPELINE COMPANY LLC
CommodityHVL OR OTHER FLAMMABLE OR TOXIC FLUID WHICH IS A GAS AT AMBI
Pipeline Typehazardous_liquid

Location

State
Coordinates30.26541, -93.41100

Cause

CauseEQUIPMENT FAILURE
SubcauseNON-THREADED CONNECTION FAILURE

Casualties

Fatalities0
Injuries0

Costs

Property Damage$200
Emergency Response$0
Other Costs$0

Location Map

Incident Narrative

"ON SEPTEMBER 26, 2024, AT 23:30 CENTRAL TIME, HOUSTON CONTROL CENTER (HCC) RECEIVED AN ESD ALARM AT THE DIXIE STEGALL PUMP STATION. HCC DISPATCHED A FIELD TECHNICIAN TO INVESTIGATE THE ALARM. THE COMPANY EMPLOYEE ARRIVED ON SITE AT 01:01 AND DETERMINED THE INJECTION FILTER VESSEL WAS LEAKING FROM THE DOOR SEAL. THE VESSEL WAS ISOLATED AND BLED DOWN IMMEDIATELY ELIMINATING THE LEAK. AN INVESTIGATION OF THE DOOR SEAL INDICATED AN O-RING SEAL HAD SEPARATED AND FAILED. A NEW O-RING SEAL WAS INSTALLED, AND THE VESSEL WAS RETURNED TO SERVICE. REVISED PART C5 FROM CARBON STEEL WITH MATERIAL OTHER THAN CARBON STEEL SPECIFYING FLUORINE KAUTSCHUK MATERIAL (FKM)."