ENTERPRISE PRODUCTS OPERATING LLC

hazardous_liquid Incident — — October 4, 2024

Incident Information

Incident DateOctober 4, 2024
OperatorENTERPRISE PRODUCTS OPERATING LLC
CommodityHVL OR OTHER FLAMMABLE OR TOXIC FLUID WHICH IS A GAS AT AMBI
Pipeline Typehazardous_liquid

Location

State
Coordinates31.74297, -98.37256

Cause

CauseMATERIAL FAILURE OF PIPE OR WELD
Subcause"DESIGN-, CONSTRUCTION-, INSTALLATION-, OR FABRICATION-RELATED"

Casualties

Fatalities0
Injuries0

Costs

Property Damage$200,000
Emergency Response$10,000
Other Costs$0

Location Map

Incident Narrative

"ON 10/4/2024 AT 09:30 AN ENTERPRISE TECHNICIAN WAS MAKING A ROUTINE STATION CHECK AT SHIN OAK ENERGY EAST PUMP STATION WHEN HE OBSERVED AN ICE BALL AROUND A TOP VENT ON PUMP DISCHARGE PIPING. THE PUMP STATION WAS IMMEDIATELY ISOLATED AND BYPASSED. REPAIR WOULD REQUIRE A SECTION OF PIPING TO BE CUT OUT AND REPLACED, RESULTING IN REPAIR COSTS EXCEEDING $50,000. RESULTS OF METALLURGICAL ANALYSIS ON THE REMOVED SECTION OF PIPING INDICATED THAT THE FAILURE WAS LIKELY DUE TO A FATIGUE CRACK. TO PREVENT RECURRENCE, STEPS HAVE BEEN TAKEN TO ASSESS AND MINIMIZE EFFECTS OF VIBRATION. NRC #1412781, 48-HOUR UPDATE #1412961."

About This Pipeline Incident

Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.

Back to All Incidents More Incidents in