ENTERPRISE PRODUCTS OPERATING LLC

hazardous_liquid Incident — — October 19, 2024

Incident Information

Incident DateOctober 19, 2024
OperatorENTERPRISE PRODUCTS OPERATING LLC
CommodityHVL OR OTHER FLAMMABLE OR TOXIC FLUID WHICH IS A GAS AT AMBI
Pipeline Typehazardous_liquid

Location

State
Coordinates31.74298, -98.37256

Cause

CauseMATERIAL FAILURE OF PIPE OR WELD
Subcause"DESIGN-, CONSTRUCTION-, INSTALLATION-, OR FABRICATION-RELATED"

Casualties

Fatalities0
Injuries0

Costs

Property Damage$250,000
Emergency Response$0
Other Costs$0

Location Map

Incident Narrative

"ON OCTOBER 19. 2024 AN ENTERPRISE TECHNICIAN WAS AT A NEARBY ENTERPRISE FACILITY WHEN AT 07:51 CDT HE OBSERVED A VAPOR CLOUD AT SHIN OAK ENERGY EAST PUMP STATION. THE HOUSTON CONTROL CENTER WAS NOTIFIED AND THE STATION WAS SHUT DOWN AND ISOLATED AT 07:52 CDT. DETERMINATION WAS MADE AT 08:17 CDT THAT A SECTION OF PIPE WOULD NEED TO BE CUT OUT AND REPLACED, AND REPAIR COSTS ARE LIKELY TO BE APPROXIMATELY $200K. RESULTS OF METALLURGICAL ANALYSIS ON THE REMOVED SECTION OF PIPING INDICATED THAT THE FAILURE WAS LIKELY DUE TO A FATIGUE CRACK. TO PREVENT RECURRENCE, STEPS HAVE BEEN TAKEN TO ASSESS AND MINIMIZE EFFECTS OF VIBRATION. NRC ORIGINAL REPORT # 1414123, 24-HOUR UPDATE # 1414258"