ONEOK NGL PIPELINE, LLC

hazardous_liquid Incident —

Incident Information

Report Date
OperatorONEOK NGL PIPELINE, LLC
Commodity—
Pipeline Typehazardous_liquid

Location

State
Coordinates32.26162, -101.27817

Cause

CauseINCORRECT OPERATION
Subcause—

Casualties

Fatalities0
Injuries0

Costs

Property Damage
Lost Commodity
Public/Private Damage
Emergency Response
Environmental Remediation
Other Costs

Location Map

Incident Narrative

ONEOK REPLACED A SECTION OF PIPE DUE TO AN IDENTIFIED PIPELINE ANOMALY ON THE #1-10-INCH NATURAL GAS LIQUIDS (NGL) PIPELINE. THE PIPELINE HAD BEEN ISOLATED, EVACUATED OF PRODUCT, AND PURGED WITH NITROGEN. NON-DESTRUCTIVE TESTING (NDT) OF THE TIE-IN WELDS IDENTIFIED A REQUIRED REPAIR. THE ONEOK HOT WORK STANDARD WAS NOT ADEQUATELY FOLLOWED, AND DURING THE WELD REPAIR A SMALL FIRE OCCURRED. THE FIRE WAS EXTINGUISHED AND WORK WAS STOPPED.

About This Pipeline Incident